Click on image(s) to enlarge
Multifunction
programmer/ step controller size 72x72mm. The ATR620 has been specifically
developed as a control system for glass, ceramics, heat treatments
kilns and furnaces.
Double display enables visualization of setpoint
and process value, selected cycle, temperature at step end, output
percentage, time elapsed from start, step in progress and power
consumption/KWh. Fast advancement on cycle and manual control of output
percentage to assure precise monitoring of the plant. If it is
necessary to monitor two zones (example: kilns with extended chamber),
the “double loop” function is very useful to compare the reading of two
sensors and keep uniform temperature inside the chamber. For each of the 15 programmable cycles, it is possible to program 20 steps/segments.
Special software functions provide high accuracy of firing profile for sensitive materials:
- Waiting function (useful when the plan cannot reach setpoint within the programmed time)
- Recovery function (with automatic or selectable gradient) in case of power failure.
Additional
features include: 2 programmable digital inputs for Start/Stop/Alarm;
operating as simple controller with programmable setpoint; starting
setpoint; relay/SSR outputs for the management of heating groups,
burners or auxiliary alarms; delaied start; Master/Slave mode for
serial line (RS485+MODBUS-RTU protocol, up to 32 control loops).
Technical
data
- SIZE: 72x72 (front fascia) x 105mm
- POWER SUPPLY: 24/115/230Vac ±10%, 50/60Hz selectable by internal dip-switch
- POWER CONSUMPTION: 4W
- DISPLAY: 4 green digits (main), 4 red digits (second display), 4 red LEDs
- OPERATING CONDITIONS: 0-45°C, 35-95rH%
- INPUTS:
- 2 inputs selectable for TC J, K, S, R, PT100, NI100, 0-1V, 0-10V, 0-20mA, 4-20mA
- 2 programmable digital inputs (if serial communication is not used)
- OUTPUTS:
- 2 relays 8A resistive + 1 SSR 12V-30mA (version ATR620-21ABC)
- 3 relays 8A resistive (version ATR620-22ABC)
- CONTROL MODE: ON/OFF, PID- Autotuning, Double loop
- ACCURACY: : 0.5% ±1digit for TC/RTD, 0.2% ±1digit for V/mA
- SAMPLING TIME: 250ms
- SEALING: IP54 Frontal, IP30 Box, IP20 Terminal blocks
- CONFIGURATION: parameters protected by password
- Memory card for quick configuration or software upgrade
- SPECIAL FUNCTIONS:
- 15 programmable cycles – 20 steps each
- Waiting function
- Recovery of interrupted cycle
- Serial communication RS485 / Modbus-RTU

See Also :